Aesthetic Surgery Journal · 2012 · 34 citations · 10 references
MedicinePlastic SurgerySurgery3D ModelingBiomedical ImagingDiagnostic ImagingBreast AssessmentBreast AugmentationBreast ReconstructionThree-dimensional ReconstructionBreast MeasurementsInter-observer ReliabilityInternal Consistency ReliabilitySilicone ImplantsSurgical SimulationThree-dimensional Imaging Of ImplantsVolumetric EstimationVolumetric Imaging
BACKGROUND: Three-dimensional (3D) digital photography uses integrated image capture technology and rendering software to create 3D models. Volumetric measurements project simulated post-operative images prior to breast augmentation. OBJECTIVES: To evaluate the accuracy and reproducibility of breast volume measurements using the Portrait 3D Surgical Simulation Platform (Axis Three, Boston, Massachusetts). METHODS: Twenty-two patients underwent breast augmentation. 3D volumetric imaging analysis was performed by two independent observers preoperatively and at 6 weeks postoperatively. Simulated volumes were compared to actual implant volume using the Student's t test. Intra-observer reliability was evaluated by measuring internal consistency (Cronbach and 95% confidence interval [CI]) and test-retest reliability (intraclass correlation coefficient [ICC]) from the two observers' calculated volumes. RESULTS: Half (n = 11) of the patients received silicone implants and half saline; all were placed in the submuscular plane through an inframammary incision. No difference in volume estimation in preoperative or postoperative images (P = .49 and P = .14; and P = 1.0 and P = .37, in right and left breasts, respectively) was observed. The test-retest reliability between observers was excellent (ICC, 0.98; P < .001) and Cronbach's value (0.99; 95% CI 0.97-0.99; P < .001) demonstrated an excellent correlation. Regarding accuracy, difference in volume estimation between actual and simulated volumes varied between 0 to 106 mL (0 - 30%), with an absolute mean difference of 12.2% (42.5 mL). CONCLUSIONS: The Portrait 3D breast imaging system provides a highly reproducible 3D tool for measuring breast volume and simulating breast augmentation. Accuracy of the 3D models can vary up to 30% (mean 12.2%). This variability should be accounted for when using this technology to visually communicate with patients.
10
A H BECKETT, M ROWLAND, P TURNER · The Lancet · 1965 · 16.9K citations
Validating Three-Dimensional Imaging of the Breast
Albert Losken, Hisham Seify, Donald D. Denson et al. · Annals of Plastic Surgery · 2005 · 233 citations