Publication | Open Access
Stability of Plasma Glucose during Storage
34
Citations
8
References
1990
Year
Plasma glucose concentrations were found to decrease during storage. This phenomenon was not method-dependent; it was demonstrated using both a Beckman Glucose Analyser 2 (based on glucose oxidase) and a hexokinase-based technique on a centrifugal analyser. The loss of glucose was typically of the order of 10% in plasma frozen for periods from 24 h to 14 months. Repeated freezing and thawing (weekly for 1 month) did not produce additional loss of glucose compared with aliquots thawed for the first time at 1 month. Fluoride did not reduce the loss of glucose. Glucose was also lost from frozen neutralized perchloric acid extracts of blood (mean +/- SD: 7 +/- 2 per cent over 1 year). We conclude that this variable loss of glucose on storage may complicate the interpretation of metabolic research procedures.