Evaluation of CT Scans and 3-D Reformatted Images for Quantitative Assessment of the Hip

Mark F. Abel, David H. Sutherland, Dennis R. Wenger, Scott J. Mubarak

Journal of Pediatric Orthopaedics · 1994 · 133 citations · 0 references

Concepts

Abstract

Hip measurements using three-dimensional (3-D) images and computed tomography (CT) scans were evaluated. The 3-D measurements proved more accurate than CT measurements of femoral and acetabular anteversion. Additionally, accurate 3-D measurements (> 99%) of the femoral neck-shaft angle were provided. Acetabular anteversion determinations by CT scans were systematically decreased as pelvic flexion increased, whereas accuracy was > 96% with 3-D images. The 3-D software allows image rotation in all three reference planes, which minimizes positional errors. A case study is provided to exemplify the shortcomings of conventional imaging techniques and the utility of the quantitative 3-D protocol.