EngineeringBiochemistryBiotechnologyAnalytical ChemistryBiosensorsSensorsAquatic ChemistryElectrochemical SensorsEnvironmental BiosensorsEnzymatic BiosensorsEnzyme-based BiosensorsSensor-based AnalysisCation ExchangeChelate EffectEnzyme-based SensorsHeavy Metal DeterminationPhosphate Ion DetectionSensor Response CharacterizationSensor TechnologyWater Quality Sensors
Abstract In a previous study, a phosphate ion (Pi) biosensor consisting of a system of chemiluminescence flow-injection analysis (CL-FIA) combined with a reaction system of maltose phosphorylase, mutarotase, and glucose-oxidase (MP-MUT-GOD) was developed without a detailed investigation of the measurements of real samples. Therefore, in this study, after characterization of the measuring conditions in the CL-FIA system for freshwater samples, we investigated the influences of dissolved substances, such as metal ions, heavy metal ions, inorganic ions, and organic substances, in freshwater on the sensor response. The results of the study indicated that there were no substances giving irreversible effects to the enzyme activities of MP, MUT, or GOD used in this sensor; however, some cations or organic substances influenced the sensor response. We then compared the effects of the elimination of the dissolved substances by a chelate reagent, ion exchange resin, or combination of ion exchange resin and UV irradiation on the sensor response. Consequently, a cation-exchange resin (sulfonated), which improved most effectively the sensor response, was chosen as a pre-treatment method. By utilizing this pre-treatment method, the sensor system could determine the Pi concentrations in 31 samples of river or pond waters in Japan. The results obtained by this sensor system and the molybdenum-blue method were compared, and a regression curve (y = 2.78x) with good correlation (r = 0.958) was obtained between them. The reason of the slope at the regression curve was discussed. Finally, we introduce a trial type of an automatic CL-FIA biosensor system for future Pi determination. †This article is dedicated to Professor Dr. Pierre Coulet, Lyon I University, on the occasion of his retirement. Keywords: Phosphate-ion determinationMaltose phosphorylaseLuminol chemiluminescenceFlow-injection analysisCation-exchange resinFreshwater Acknowledgments The authors gratefully acknowledge the financial support for this work from the International Center for Environmental Technology Transfer (ICETT) and the receipt of freshwater samples from the Kanto Engineering Laboratory of the Ministry of Construction. Notes †This article is dedicated to Professor Dr. Pierre Coulet, Lyon I University, on the occasion of his retirement.
16
Trienzymatic biosensor for the determination of inorganic phosphate
Christine Mousty, Serge Cosnier, Dan Shan et al. · Analytica Chimica Acta · 2001 · 71 citations
Engineering, Biochemistry, Chemistry +11
A novel enzyme sensor for the determination of inorganic phosphate
N. Conrath, Bernd Gründig, St. Hüwel et al. · Analytica Chimica Acta · 1995 · 67 citations
Engineering, Biochemistry, Chemistry +13