International Journal of Environmental & Analytical Chemistry · 1979 · 19 citations · 2 references
Environmental MonitoringEngineeringChemical CompositionAir QualityPrecipitation SampledAcid PrecipitationEarth SciencePrecipitationPrecipitation ProcessesEnvironmental ChemistryAtmospheric ScienceAerosol SamplingCollectors SamplesHydrometeorologySo2 4Environmental PollutionEnvironmental QualityWater QualityIdentical CollectorsEnvironmental EngineeringFlat Area
Abstract Twenty-one raincollectors were placed together in a flat area. From 11 collectors samples were taken on a daily basis and from 10 collectors on a monthly basis. The results of the analysis for SO2 4, CI−, NO+,3 NH+ 4 Na+, Pb2+ and pH of the daily samples agreed my well. The results of the monthly samples, analysed for CI−, Na+, Ca2+, Fe3+, F−, Pb2+, Zn2+, Cd2+, and Cu2+, were less satisfactory. Differences up to 507; are found between the results of daily and monthly samples.
2