Internal CuringWater Vapour PermeabilityEngineeringEnvironmental EngineeringCivil EngineeringConcrete TechnologyWater PurificationCeramic MembraneWater TreatmentMembrane CharacterizationEfficiency IndexMembrane PermeationMembrane ProcessMembrane TechnologyMembrane Curing
This Paper describes the developmental work undertaken to enable the measurement of the water vapour permeability of a curing membrane and shows that a single-cell transmission test method which is inexpensive, versatile andeasy to operate can be usede effectively for this purpose. The water vapour permeability of a curing menzbrane determines that mernbrane's intrinsic moisture retention characteristic and is shown to provide a more reliable peyformance indicator for membrane curing of concrete than the commonlJ1 used curing efficiency index, which is an empirical and relative value that depends on a particular test method and measuring system.