IEEE Transactions on Nuclear Science · 1975 · 24 citations · 7 references
EngineeringElectrical EngineeringAnalog ElectronicsLow-power DesignMicroelectronicsBaseline MeasurementPulse ProcessingPulse Processing ElectronicsSignal AmplificationSignal ConditioningBaseline RestorationBaseline Shift AnalysisPulse AmplificationPulse ConditioningPulse Generator CircuitsRecovery TimeUndershoot
A baseline restorer (BLR) for pulse amplifiers is described in which current to the memory capacitor can be gated off during a pulse. This technique reduces the BLR recovery time without introducing artifacts when a short-period undershoot accompanies the input signal. The gating and reset thresholds are adjustable, as is the BLR symmetry. Tests with a pulse generator show that the baseline shift with 5V pulses at duty factors up to 75% is less than 1mV. When the signal source is a radiation detector, the gated BLR is usable at duty factors up to 90%.
7