EngineeringElectrical EngineeringMechanical EngineeringElectric MachinesMachine DesignPower ElectronicsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsLosses In Electric MachinesMachine CoolingCurrent DensityCurrent Flow ModelingEddy Current AnalysisElectric Motor CoolingEquivalent Circuit AnalysisEquivalent Circuit ModelingInverter SystemsMotor Cooling
The high-frequency (HF) circulating bearing current that may occur in the machines of the inverter-based drive systems can be reduced or even completely suppressed by the use of the electrically insulated bearings or the insulated inner bearing seats. This paper proposes a method to calculate the influence of the thickness of the insulating coat on the obtained current reduction as a function of the several machine-design parameters. The parameters of the equivalent circuit are derived from an eddy-current model. The calculation considers the transient nature of the current flow. For the standard fan-cooled motors with up to 500-kW rated power, a minimum thickness of the insulating coat of 250 mum is required to reduce the circulating bearing currents to values where the apparent bearing-current density is less than 0.1 A/mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> , which is commonly taken as the threshold to the bearing failure
15