Catheterization and Cardiovascular Interventions · 2011 · 18 citations · 16 references
MedicineChild HealthPediatricsHemostasisPediatric CardiologyVascular SurgeryCardiac CatheterizationHemostasis ManagementPediatric AnesthesiaPediatric Anesthetic TechniquesCompressionFemoral Venous AccessPediatric CatheterizationPediatric HemostasisPediatric Vascular Access SafetyPediatric Venous AccessVascular Access In ChildrenVascular Closure Devices
BACKGROUND: Femoral venous and arterial approaches are the commonly used to obtain vascular access for pediatric cardiac catheterization. Hemostasis after catheter removal is usually obtained by manual compression. However, this technique is time consuming and at times painful. Although several closure devices are available for adults, they are not widely applicable in children. OBJECTIVES: To evaluate the safety and efficacy of a microporous polysaccharide hemospheres hemostasis (MPH) bandage compared to manual compression. METHODS: Prospective randomized study, involving 112 children after cardiac catheterization. One group received the MPH bandage, another manual compression. Compression time was predetermined by the size of sheath plus one minute. Success was defined as no bleeding or hematoma formation. If bleeding continued, compression was continued as needed and time to hemostasis recorded. Informed consent was obtained prior to randomization. Group comparisons were performed with a Student's t, Pearson's Chi Square, and Fisher's exact test as appropriate. RESULTS: Fewer children required a compression time of >15 min (P = 0.006) and more had a shorter time to hemostasis (P = 0.003) in the MPH group for venous access control. Time to hemostasis was also shorter in the MPH (P = 0.048) in arterial access cases, but the number of children requiring a compression time >15 min was the same. Complications including hematoma formation in each group were similar. CONCLUSIONS: The MPH bandage allows a shorter time to achieve hemostasis compared to manual compression. This improves turnaround time and laboratory efficiency.
16
Complications of femoral artery closure devices
Daniel Carey, JoAnn R. Martin, Carl A. Moore et al. · Catheterization and Cardiovascular Interventions · 2001 · 172 citations
Medicine, Surgery, Orthopedics +10
The Seldinger technique: 50 years on
ZCJ Higgs, DAL Macafee, BD Braithwaite et al. · The Lancet · 2005 · 149 citations
The use of the Angioseal device for femoral artery closure
Alan Abando, Douglas B. Hood, Fred A. Weaver et al. · Journal of Vascular Surgery · 2004 · 118 citations