Journal of Structural Engineering · 1990 · 72 citations · 6 references
EngineeringCivil EngineeringBuilding StructuresStructural AnalysisStructural EngineeringStructural DesignStructural LoadsStructural MechanicsStructural Response AnalysisEccentricityMomentsMultistory Frame AnalysisTorsional BehaviorTorsional Rigidity
This paper clarifies the definitions of eccentricity used in two of the approaches to calculate story torsional moments in the design of torsionally unbalanced regular multistory structures. One approach uses the floor eccentricities, in conjunction of the static equivalent loading, to calculate the floor torques. The story torsional moment is then obtained by summing the floor torques above the story. This approach was suggested in the Recommended Lateral Force Requirements and Commentary by the Structural Engineers Association of California. In this approach, the floor eccentricity should be defined as the distance between the generalized center of rigidity and the load resultant at that floor. In the second approach, the story torsional moment is obtained directly as the product of story shear and the story eccentricity, as suggested by Uniform Building Code. In this approach, the story eccentricity should be defined as the horizontal distance between the shear center at the story and the resultant of all lateral forces above the story being considered. It is shown that if the proper definitions of eccentricity are used, both approaches result in the same story torsional moments. A simple example is worked out in detail to show the steps involved in each of the approaches.
6
Design for seismic torsional forces
J. L. Humar · Canadian Journal of Civil Engineering · 1984 · 40 citations