Radiology · 2008 · 221 citations · 27 references
MedicineRadiologySurgeryDiagnostic ImagingDiagnostic RadiologyVascular SurgeryAneurysm RepairAneurysm SurgeryAortic Aneurysm RepairAortic ImagingComputed TomographyVascular ImagingDiagnostic Performance MetricsDual-energy Computed TomographyElective Aortic Aneurysm RepairEndovascular Aortic Aneurysm RepairEndovascular Aortic Repair ImagingEndovascular Repair ImagingEndovascular Vascular RepairVirtual Images
PURPOSE: To assess the diagnostic performance of dual-energy dual-source computed tomography (CT) in the detection of endoleaks after endovascular abdominal aortic aneurysm (AAA) repair. MATERIALS AND METHODS: This study was local ethics board approved, and written informed consent was obtained from all patients. One hundred eighteen patients (21 women, 97 men; mean age, 74 years +/- 8 [standard deviation]) underwent follow-up dual-energy dual-source CT during the nonenhanced, arterial, and delayed phases after AAA repair. Delayed phase CT images were acquired in the dual-energy mode for reconstruction of virtual nonenhanced images. Two blinded and independent readers evaluated the data for the presence or absence of endoleaks during three reading sessions: Standard nonenhanced, arterial phase, and delayed phase images were read during session A; virtual nonenhanced, arterial phase, and delayed phase images, during session B; and virtual nonenhanced and delayed phase images, during session C. Sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) were calculated, with the session A image data set as the reference standard. Radiation dose parameters were estimated. RESULTS: Reading session A revealed that 52 (44%) of 118 patients had endoleaks. Overall sensitivity, specificity, NPV, and PPV for CT endoleak detection during sessions B and C were identical: 100%, 97%, 100%, and 96%, respectively. The accuracy of the session B and session C readings was not significantly different from that of the session A reading (P = .50). The effective radiation dose in the image acquisition protocol involving one dual-energy scan was significantly (P < .001) lower than the effective doses in the protocols involving standard triple-phase scanning (mean difference, 61%) and standard nonenhanced and delayed phase scanning (mean difference, 41%). CONCLUSION: Compared with standard protocols, one dual-energy dual-source CT scan performed during the delayed phase with reconstruction of virtual nonenhanced images enables detection of endoleaks after endovascular AAA repair with high accuracy and a considerably lower radiation dose.
27
Material differentiation by dual energy CT: initial experience
Thorsten R. C. Johnson, Bernhard Krauß, Martin Sedlmair et al. · European Radiology · 2006 · 1.5K citations
First performance evaluation of a dual-source CT (DSCT) system
Thomas Flohr, Cynthia H. McCollough, Herbert Bruder et al. · European Radiology · 2005 · 1.4K citations
Endoluminal Stent–Grafts for Infrarenal Abdominal Aortic Aneurysms
Ulrich Blum, Götz Voshage, Johannes Lämmer et al. · New England Journal of Medicine · 1997 · 678 citations · Full text