American Journal of Analytical Chemistry · 2013 · 43 citations · 33 references
Flow Injection SystemEngineeringChemistryChemical EngineeringEnvironmental ChemistryElectron MicroscopyEnvironmental Analytical ChemistryBioremediationLinde TypeAnalytical ChemistryZeoliteElemental CharacterizationTrace ElementMaterials ScienceInorganic ChemistryFlow Injection AnalysisType Y FaujasiteWater AnalysisEnvironmental EngineeringSpectroscopyNatural SciencesEnvironmental RemediationFia ConfigurationEnvironmental Toxicology
In this work, a flow injection analysis (FIA) method for the trace determination of lead, cadmium, nickel and cobalt in natural waters by formation of neutral chelates with ammonium pyrrolidine dithiocarbamate (APDC) was developed. The neutral chelates formed was retained in a mini-column packed with Linde type A zeolite (LTA) and type Y Faujasite zeolite (FAU) and then eluted with methyl isobutyl ketone (MIBK) to flame atomic absorption spectrometry (EAA) for its detection. Physicochemical characterization of this zeolite was carried out by Fourier Transform infrared spectroscopy and attenuated total reflectance (FTIR and IR-ATR), scanning electron microscopy and energy dispersive X-ray microanalysis (SEM-EDX) and X-ray power diffraction (XRD). Then, a FIA configuration was used with a column preconcentration system coupled to the detection system at room temperature (22?C). The detection limit and the relative standard deviation for 5 determinations of different solutions of Pb2+, Co2+, Ni2+ and Cd2+ for FAU and LTA zeolite were calculated. The sampling frequency ranged from 18-35 h-1 and preconcentration factors from 21-250 were achieved, for a sample volume of 6 mL using 20 mg of sorbents, indicating a high retention of the analytes on the zeolites material. The recoveries obtained in natural waters samples were close to 100% for all ions metal using synthetic zeolites, confirming the applicability of the method. The isotherm models of Langmuir, Scatchard, Freundlich and Dubinin-Radushkevich were used to study the equilibrium data, indicating that successfully followed the Freundlich and Dubinin-Radushkevich (D-R) isotherms at low metal ion concentration. The Freundlich parameter n varied between 0.35-1.01, whereas D-R isotherm yields the sorption free energy E 8 kJ.mol-1 indicating psysisorption.
33
Alana Gonzales, M.A. Firmino, Cassiana Seimi Nomura et al. · Analytica Chimica Acta · 2009 · 332 citations
Organic Geochemistry, Biogeochemistry, Environmental Chemistry +12
Cheng Guihong, Man He, Hanyong Peng et al. · Talanta · 2011 · 165 citations
Nanoparticles, Materials Science, Environmental Chemistry +14
Mohammad Reza Nabid, Roya Sedghi, Akbar Bagheri et al. · Journal of Hazardous Materials · 2011 · 138 citations
Extractive Metallurgy, Chemical Engineering, Selective Separation +7