Identifying the Ciliary Sulcus for Suturing a Posterior Chamber Intraocular Lens by Transillumination

Masayuki Horiguchi

Archives of Ophthalmology · 1993 · 22 citations · 5 references

Concepts

Abstract

We describe herein a technique for locating the ciliary sulcus for suturing a posterior chamber intraocular lens. Transscleral illumination with a light-guide fiber placed underneath the iris reveals the ciliary sulcus as a bright area near the limbus, and it allows for a straight needle with 10-0 polypropylene fiber to be easily inserted through the sulcus after making two pairs of radial scleral incisions to fixate the 10-0 polypropylene fiber. We think that this procedure can minimize complications of suturing a posterior chamber intraocular lens and shorten the operation time.

References

5