Alterations in blood pressure during exchange transfusion.

Jacobv . Aranda, A. Y. Sweet

Archives of Disease in Childhood · 1977 · 25 citations · 9 references

DOIFull text

Open access

Concepts

Abstract

Blood pressure changes as a function of the rates of blood withdrawal and infusion were determined during exchange blood transfusion in 2 preterm newborn infants. 10 ml blood withdrawal and infusion completed within 3 minutes resulted in reversible changes in aortic pressure, whereas the same procedure completed within 45 to 60 seconds resulted in a progressive fall in the systolic pressure and in narrowing of the pulse pressure. In one of the cases this was associated with respiratory arrest. An exchange rate of 5 ml/kg per 3 minutes is recommended.

References