Pressure-Grouting Drilled Shaft Tips in Sand

Gray Mullins, Steven Dapp, Peter Lai

2000 · 48 citations · 1 references

Concepts

Abstract

Considering the strain incompatibility between end bearing and side friction of drilled shafts, tip capacity is often discounted from total shaft capacity. This is due to the relatively large displacements required to mobilize the tip which often exceed service load displacement criteria. Additionally, concerns regarding shaft tip soil disturbance (i.e. insitu stress relief) and toe cleanliness further discourage designers from using end bearing as available capacity. As a method of mitigating these conditions, pressure-grouting the shaft tip after its construction has been successfully employed throughout the world. With very few exceptions, the benefits of tip-grouting have been disregarded in the United States. Sources of skepticism arise from the uncertainty of the grout formation beneath the tip and the lack of rational design procedures for its use. In cooperation with the Florida Department of Transportation, the University of South Florida is researching the effects of post-grouting on shaft capacity in loose to medium dense sands. This paper presents a review of past and present base-grouting methods used throughout the world and the scope of on-going full-scale load test programs.

References

1