The Preparative Scale Separation of Multicomponent Mixtures by Continuous Gas Liquid Chromatography

P. E. Barker, D. H. Huntington

Journal of Chromatographic Science · 1966 · 15 citations · 0 references

Concepts

Abstract

The operating ranges of the air and solid flowrates to give complete separation of the cyclohexane/methylcyclohexane/benzene mixture using a 2.54 cm. diameter main column and 1.27 cm. diameter side arm continuous gas-liquid chromatography apparatus have been determined. In these experiments polyoxyethylene 400 diricinoleate on Johns Manville C22 firebrick (10–22 and 14–18 B.S. mesh) was used. The mass transfer efficiency of the column expressed in heights of a transfer unit, HOG, showed the higher efficiency of smaller diameter columns, the decrease in the efficiency of the column on reducing the percentage solvent from 29.6 to 13.0, and the change in HOG values with column height. The factors affecting the design of moving bed columns are given together with experimental data on the use of reflux in moving bed chromatography work. Finally, details of a new circular chromatography column are given for the continuous and batch separation of liquid or gaseous mixtures. Complete separation of the system diethylether/dichloromethane was achieved with a feed rate of 117.2 mls/hr. and products purities of greater than 97% were obtained at 176 mls/hr. The systems benzene cyclohexane and dimethoxymethane/dichloromethane have also been studied.