Robustness and Performance Analysis for the Linear Quadratic Gaussian/Loop Transfer Recovery with Integral Action Controller Applied to Doubly Fed Induction Generators in Wind Energy Conversion Systems

Vandilberto Pereira Pinto, J.C.T. Campos, Laurinda L. N. dos Reis, Cursino B. Jacobina, Nady Rocha

Electric Power Components and Systems · 2011 · 21 citations · 16 references

Concepts

Abstract

Abstract This article presents a novel application of the multivariable robust controller linear quadratic Gaussian/loop transfer recovery with integral action to a doubly fed induction generator. Furthermore, this study investigates robustness and performance in the face of variations of internal parameters of the machine and speed. Experimental results obtained from a laboratory prototype that uses a 2-kW machine are presented to validate and demonstrate the robustness and performance of the proposed controller through the comparison with the proportional and integral controller employed in a wind energy conversion system with doubly fed induction generator machines.

References

16