Heat flow at Cobar, New South Wales

A. E. Le Marne, J.H. Sass

Journal of Geophysical Research Atmospheres · 1962 · 16 citations · 3 references

Concepts

Abstract

From temperature measurements in two deep drill holes at Cobar, N.S.W., the mean geothermal gradient was calculated as (0.63±0.03)°C/100 ft, with a mean extrapolated surface temperature of (21.5±1.0)°C. Determination of thermal conductivity on 16 sections of drill cores from the same holes gave a mean of (10.6±1.1) mcal/sec cm °C. The geothermal flux was (2.18±0.33) μcal/cm.2sec.

References

3