X-ray focusing with lobster-eye optics: a comparison of theory with experiment

Andrew G. Peele, K. Nugent, Andrei V. Rode, K. Gäbel, M.C. Richardson, Richard R. Strack, Walter P. Siegmund

Applied Optics · 1996 · 48 citations · 18 references

DOIFull text

Open access

Concepts

Abstract

We report an experimental investigation and comparison with simulation of the x-ray focusing of a flat, square profile microchannel plate. We use x rays with an energy of ~1.5 keV from a laser-produced plasma. The images were recorded with x-ray film. We find the focal structure to be consistent with theoretical expectations. The angular resolution of the focus is 0.96 mrad, which is a major improvement over previous results. The measured peak intensity gain is 27 ± 4, which is ~33% of that for a perfect optic.

References

18