A Method for Correlating the Characteristics of Centrifugal Pumps in Two-Phase Flow

J. Mikielewicz, David Gordon Wilson, Albert Louis Goldfinch

Journal of Fluids Engineering · 1978 · 49 citations · 0 references

Concepts

Abstract

The semiempirical method described combines the ideal performance of a centrifugal pump with experimental data for single and two-phase flow to produce a so-called “head-loss ratio,” which is the apparent loss of head in two-phase flow divided by the loss of head in single-phase flow. This head-loss ratio is shown to be primarily a function of void fraction. It is demonstrated that the measured characteristics of a centrifugal pump operating in two-phase flow in normal rotation and normal and reversed flow directions (first and second -quadrant operation) and in reversed rotation and reversed flow direction (third-quadrant operation) can be reproduced with acceptable accuracy.