Physics in Medicine and Biology · 2010 · 251 citations · 30 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyMedical PhysicsComputed TomographyComputed Tomography PhysicsPatient-specific DosimetryAccuracyAtomic Number DependenceDual-energy Computed TomographyDual-energy ImagingEffective Atomic Number
The true potential of the DECT method achieved in theoretical conditions may not be fully achievable in clinical settings. Further research and development may be needed to take advantage of the DECT method to characterize individual human tissues. In a simulation study, SPRs were derived from calculated CT numbers of known material compositions and the DECT method’s accuracy was evaluated against the stoichiometric calibration method for standard human tissues and their variance, without analyzing imaging artifacts such as beam hardening, scatter, noise, or patient movement. An empirical ln Im–EAN relationship enables patient‑specific SPR calculation with DECT, and the method achieves RMS errors below 1% for standard tissues while being less sensitive to small compositional perturbations than the stoichiometric calibration method, suggesting DECT may better support accurate charged‑particle therapy planning.
We discovered an empirical relationship between the logarithm of mean excitation energy (ln Im) and the effective atomic number (EAN) of human tissues, which allows for computing patient-specific proton stopping power ratios (SPRs) using dual-energy CT (DECT) imaging. The accuracy of the DECT method was evaluated for 'standard' human tissues as well as their variance. The DECT method was compared to the existing standard clinical practice—a procedure introduced by Schneider et al at the Paul Scherrer Institute (the stoichiometric calibration method). In this simulation study, SPRs were derived from calculated CT numbers of known material compositions, rather than from measurement. For standard human tissues, both methods achieved good accuracy with the root-mean-square (RMS) error well below 1%. For human tissues with small perturbations from standard human tissue compositions, the DECT method was shown to be less sensitive than the stoichiometric calibration method. The RMS error remained below 1% for most cases using the DECT method, which implies that the DECT method might be more suitable for measuring patient-specific tissue compositions to improve the accuracy of treatment planning for charged particle therapy. In this study, the effects of CT imaging artifacts due to the beam hardening effect, scatter, noise, patient movement, etc were not analyzed. The true potential of the DECT method achieved in theoretical conditions may not be fully achievable in clinical settings. Further research and development may be needed to take advantage of the DECT method to characterize individual human tissues.
30
Report of the task group on reference man
Annals of the ICRP · 1979 · 1.7K citations
Social Sciences, Organization Studies, Cognitive Psychology +8
First performance evaluation of a dual-source CT (DSCT) system
Thomas Flohr, Cynthia H. McCollough, Herbert Bruder et al. · European Radiology · 2005 · 1.4K citations
Tissue Substitutes in Radiation Dosimetry and Measurement
Roger J. Cloutier · Radiation Research · 1989 · 1.1K citations
XCOM: Photon Cross Section Database (version 1.2)
M. J. Berger, J.H. Hubbell, S. M. Seltzer et al. · 1999 · 857 citations