PCI Journal · 2001 · 34 citations · 5 references
EngineeringCivil EngineeringBuilding MaterialsGeotechnical EngineeringStructural EngineeringCapacity DesignDeep FoundationsPile FoundationsPrestressed ConcreteEmbedmentEmbedment MechanicsPile CapsPile-soil InteractionPrecast Prestressed Concrete
This investigation studied the capacity of square pile-to-pile cap connections where the precast-prestressed pile is simply embedded in the cast-in-place pile cap. Both experimental and analytical results are presented. It is shown that the plain embedment can develop the flexural capacity of the pile without distress to the pile cap of connection region provided that a sufficient embedment length is furnished. Equations for determining the required embedment length are provided. For design purposes, it is recommended that a plain embedment length equal to the width of the embedded pile be used.
5
Precast Concrete Connections With Embedded Steel Members
Kostas Marcakis, Denis Mitchell · PCI Journal · 1980 · 68 citations · Full text
Seismic Design of Prestressed Concrete Piling
D. Sheppard · PCI Journal · 1983 · 30 citations