Lead‐Acid Battery Cathodes Incorporating Chemically Prepared PbO2

P.T. Moseley, Nevill J. Bridger

Journal of The Electrochemical Society · 1984 · 17 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

The published literature is short on evidence to support the claim that chemically prepared PbO/sub 2/ cannot be used in a lead-acid cell, and a recent attempt to quantify the effect led to the contrary result: that there was no less capacity available from a plate prepared with chemically prepared PbO/sub 2/ than from a commercially available plate. Lead dioxide prepared by the action of nitric acid on Pb/sub 3/O/sub 4/ was mixed with dry polytetrafluoroethylene (PTFE) powder (1 weight percent (w/o)), and pressed into a battery grid from which the commercial product had been removed. Capacity measurements were made by low rate discharge through a resistor. The experiments reported here were designed to extend the testing of chemical PbO/sub 2/ capacity to constant current discharge, to explore the range of binder content necessary to perform the function of the conventional curing process in retaining the active material in the grid, and to try to discover at what stage the difference in hydrogen content between chemical and electrochemical PbO/sub 2/ develops.