Medical Physics · 2009 · 229 citations · 11 references
MedicineRadiation OncologyClinical Radiation OncologyRadiation DosimetryTreatment PlanningIntensity-modulated RadiotherapyPatient Dose OptimizationRadiation TherapyRadiation Treatment PlanningTreatment Planning Dose CalculationTreatment Planning PhysicsIntensity-modulated Radiation Therapy DosimetryMachine Parameter OptimizationMotion ConstraintsTreatment Plan OptimizationTreatment Planning DosimetryVolumetric Modulated Arc Therapy Dose CalculationVolumetric Modulated Arc Therapy DosimetryVolumetric Modulated Arc Therapy Planning
The authors developed an efficient VMAT planning method that uses a single arc with continuous variation of multileaf collimator positions, dose rate, and gantry speed, derived from coarsely sampled fluence maps and optimized via direct machine‑parameter optimization, and is applicable to any current linear accelerator. When applied to ten patients, the method produced plans with comparable or improved dosimetric quality versus step‑and‑shoot IMRT, reduced delivery times to 70–160 s, and lowered monitor units in nine of ten cases.
An efficient method for volumetric intensity modulated arc therapy (VMAT) planning was developed, where a single arc (360° or less) is delivered under continuous variation of multileaf collimator (MLC) segments, dose rate, and gantry speed. Plans can be generated for any current linear accelerator that supports these degrees of freedom. MLC segments are derived from fluence maps at relatively coarsely sampled angular positions. The beam segments, dose rate, and gantry speed are then optimized using direct machine parameter optimization based on dose volume objectives and leaf motion constraints to minimize arc delivery time. The method can vary both dose rate and gantry speed or alternatively determine the optimal plan at constant dose rate and gantry speed. The method was used to retrospectively generate variable dose rate VMAT plans to ten patients (head and neck, prostate, brain, lung, and tonsil). In comparison to step‐and‐shoot intensity modulated radiation therapy, dosimetric plan quality was comparable or improved, estimated delivery times ranged from 70 to 160 s, and monitor units were consistently reduced in nine out of the ten cases by an average of . Optimization and final dose calculation took between 5 and 35 min depending on plan complexity.
11
Volumetric modulated arc therapy: IMRT in a single gantry arc
Karl F. Otto · Medical Physics · 2007 · 1.9K citations · Full text
Medicine, Radiation Oncology, Clinical Radiation Oncology +16
User's Guide for SOL/NPSOL: A Fortran Package for Nonlinear Programming.
Philip E. Gill, Walter Murray, Michael A. Saunders et al. · 1983 · 260 citations