European Heart Journal · 2011 · 131 citations · 39 references
MedicineCardiologyPharmacotherapyBiomedical ImagingBiomedical OpticsInterventional CardiologyArterial InterventionsCoronary Artery DiseaseCoronary Artery ImagingIntravascular ImagingOptical Coherence TomographyStent PlacementCoronary Stent RestenosisCovered Stent PlacementStent BiomaterialsStent Patency AssessmentStent Placement ImagingStent Thrombosis PreventionVascular StentingVascularized Tissue Coverage
AIMS: To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an 'all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. METHODS AND RESULTS: Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas-volumetric parameters were found between ZES and EES, respectively. CONCLUSION: No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-up.
39
Pathology of Drug-Eluting Stents in Humans
Michael Joner, Aloke V. Finn, Andrew Farb et al. · Journal of the American College of Cardiology · 2006 · 2.7K citations
Medicine, Cardiology, Pathology +11
Localized Hypersensitivity and Late Coronary Thrombosis Secondary to a Sirolimus-Eluting Stent
Renu Virmani, Giulio Guagliumi, Andrew Farb et al. · Circulation · 2004 · 1.5K citations · Full text
Medicine, Cardiology, Immunology +13
Pathological Correlates of Late Drug-Eluting Stent Thrombosis
Aloke V. Finn, Michael Joner, Gaku Nakazawa et al. · Circulation · 2007 · 1.3K citations · Full text