Journal of Pediatric Orthopaedics · 2005 · 21 citations · 22 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryOrthopedicsPediatric OrthopaedicsPediatric Orthopedic SurgeryHip DisordersHip InjuriesPediatric Hip DisordersPediatric OrthopedicsPediatric UltrasoundClinical Screening TestsClosed Joint ReductionLate Diagnosis SurveillanceNeonatal Hip UltrasonographyNeonatal Hip UltrasoundPediatric Hip UltrasoundUltrasound Of The Hip
This article reports the results of a neonatal hip screening program comprising clinical screening and targeted ultrasound performed by orthopaedic surgeons. Over 7 years, from 1995 to 2001, there were 15,397 live births in the authors' region. Seven hundred thirty-three babies (4.8% of births) were referred for hip ultrasound: 80% for risk factors and 20% for instability. Eighty-three babies (5.4/1,000) were splinted in a Pavlik harness. Three of these subsequently required surgery (1.9/1,000). Ten patients (0.65/1000) presented with hip dislocation after 12 weeks of age, nine of whom required open or closed reduction (0.56/1,000). From 1978 to 1985, when neonatal pediatricians clinically screened all babies, 18 babies presented late from 13,707 births (1.3/1000). Since the introduction of orthopaedic screening and targeted ultrasound, there has been a significant reduction in late diagnosis in the authors' institution.
22
The infant hip: real-time US assessment of acetabular development.
C. Morin, H. Theodore Harcke, G. Dean MacEwen · Radiology · 1985 · 219 citations