Measurements of Thomson Coefficients for Metals at High Temperatures and of Peltier Coefficients for Solid-Liquid Interfaces of Metals

J. J. Lander

Physical Review · 1948 · 52 citations · 4 references

Concepts

Abstract

Apparatus has been devised for measuring and measurements made of Thomson coefficients of metals at high temperatures. It is found that in the range from 400\ifmmode^\circ\else\textdegree\fi{}C to the melting point the approximation $\ensuremath{\sigma}=\ensuremath{\beta}T$ is adequate for platinum, palladium, copper, and silver but not for gold, molybdenum, and tungsten.Experimental results for the Peltier coefficients for solid-liquid interfaces of gold, silver, and copper are also reported. An experimental sensitivity of 0.1 millivolt revealed no effect in gold and silver, but + 10.2 millivolts were obtained for copper.

References

4