Concepedia

Publication | Closed Access

Initial test results from the Palomar 200-in. adaptive optics system

22

Citations

0

References

1997

Year

Abstract

We present laboratory subsystem test results obtained during integration of the Palomar 200” Adaptive Optics System at Jet Propulsion Laboratory. These results pertain to the 241 actively controlled actuator, Shack-Hartmann sensed, initial delivery of a system optimized for near infrared observation with the 5 meter diameter telescope at Palomar Mountain. This system initially exploits natural guide stars. Our intention is to provide a wide-ranging summary of subsystem performance measurements and several lessons learned. Noteworthy among these results is our measurement of 6.3 ± 0.2 electron read noise performance of our initial WFS camera, based upon a 64 x 64 pixel MIT/LL CCD detector, running at 600 kilopixel per sec per output amplifier. This camera was constructed by SciMeasure Analytical Systems, Inc. of Decatur, GA.