Publication | Closed Access
Quality control of red cell filtration at the patient's bedside
21
Citations
12
References
1994
Year
The RBC filtration at the patient's bedside can be equal in quality to that performed in the laboratory, at least in such clinical settings as hematology and oncology departments in which blood transfusion is common practice, and if simple training is provided to the nursing staff. Under the conditions of this study, it seems that quality control of RBC bedside filtration is feasible and simple.