Circulation Research · 1982 · 106 citations · 21 references
MedicineCardiologyAnesthesiaHemodynamic ManagementPulmonologyBlood Pressure Signal AnalysisCirculatory PhysiologyHemodynamic PharmacologyHemodynamic Response To AnesthesiaHemodynamicsPulmonary HypertensionArterial ComplianceCirculationHemodynamic Wave PropagationNitroprusside TherapyPulmonary Arterial PressurePulmonary Artery Pressure MeasurementPulmonary CirculationVascular Resistance
We have studied the effect of changes in pulse wave reflection on the configurations of pressure and flow in systemic and pulmonary circulation. Electromagnetic flow transducers, atrial catheters, and pacing leads were implanted in 10 dogs. In four animals, the flow transducer was placed on the pulmonary artery, in another four on the ascending aorta, and in two additional dogs on both vessels. One week later, ascending aortic and/or pulmonary artery flow and pressure (catheter tip manometer) were measured under general anesthesia (Nembutal, 30 mg/kg, iv). When the pulmonary circulation was studied (six dogs), measurements were made before and during serotonin infusion (0.5-0.75 mg/min). When the systemic circulation was studied (six dogs), measurements were made before and during nitroprusside infusion (50-200 micrograms/min). To quantify the arterial load, we calculated pulmonary and systemic input impedances. To estimate the amount of reflection, we used a reflection index which we defined as the amplitude ratio of reflected and forward wave. Nitroprusside decreased total peripheral resistance, increased total arterial compliance, and decreased the reflection index; similarity between aortic pressure and flow wave shapes increased, and they looked more like their pulmonary counterparts. Serotonin increased pulmonary vascular resistance, decreased pulmonary arterial compliance, and increased the reflection index. Resemblance of pressure and flow waves decreased. The differences in wave shapes can thus be explained by the amount of reflection: the less reflection the more pressure and flow resemble each other.
21
Donald A. McDonald · The American Journal of the Medical Sciences · 1963 · 1.6K citations
Medicine, Anatomy, Physiology +12
The dynamic elastic properties of the arterial wall
D. H. Bergel · The Journal of Physiology · 1961 · 910 citations
Forward and backward waves in the arterial system
Nicolaas Westerhof, P. Sipkema, G. C. van den Bos et al. · Cardiovascular Research · 1972 · 675 citations
An artificial arterial system for pumping hearts.
Nico Westerhof, G. Elzinga, P. Sipkema · Journal of Applied Physiology · 1971 · 547 citations
Medicine, Bioengineering, Cardiology +10
Arterial impedance as ventricular afterload.
William R. Milnor · Circulation Research · 1975 · 370 citations
Medicine, Cardiology, Physiology +10