Respirator cartridge efficiency studies: VII. effect of relative humidity and temperature

G.O. Nelson, A. NICHOLAS CORREIA, C.A. Harder

American Industrial Hygiene Association Journal · 1976 · 55 citations · 0 references

Concepts

Abstract

Cartridge service life is not appreciably affected at relative humidities below 50%. However, performance is severely compromised when the humidity exceeds 65%. Experimental values are compared from those calculated from the adsorption isotherm, Mecklenburg and modified Wheeler equations. Calculations indicate that temperature does not play a significant role in service life predictions.