Journal of Turbomachinery · 1996 · 47 citations · 10 references
EngineeringAerospace EngineeringAerodynamicsFluid DynamicsHeat TransferFlow MeasurementNozzle FlowTransonic AerodynamicsWake Field AnalysisCoolant Flow DynamicsMach NumberOil Flow VisualizationPressure Profile AnalysisSecondary FlowsTemperature ProfilesWake DynamicsWake Flow
A trailing edge cooled low aspect ratio transonic turbine guide vane is investigated in the VKI Compression Tube Cascade Facility at an outlet Mach number M2, is = 1.05 and a coolant flow rate m˙c/m˙g = 3 percent. The outlet flow field is surveyed by combined total-directional pressure probes and temperature probes. Special emphasis is put on the development of low blockage probes. Additional information is provided by oil flow visualizations and numerical flow visualizations with a three-dimensional Navier–Stokes code. The test results describe the strong differences in the axial evolution of the hub and tip endwall and secondary flows and demonstrate the self-similarity of the midspan wake profiles. According to the total pressure and temperature profiles, the wake mixing appears to be very fast in the near-wake but very slow in the far-wake region. The total pressure wake profile appears to be little affected by the coolant flow ejection.
10
Assessment of Unsteady Flows in Turbines
Om P. Sharma, G. F. Pickett, R. H. Ni · Journal of Turbomachinery · 1992 · 99 citations
The VKI Compression Tube Annular Cascade Facility CT3
C. H. Sieverding, Tony Arts · Volume 5: Manufacturing Materials and Metallurgy; Ceramics; Structures and Dynamics; Controls, Diagnostics and Instrumentation; Education · 1992 · 36 citations
Engineering, Aerospace Engineering, Mechanical Engineering +17