Transient flow of highly concentrated suspensions investigated using the ultrasound velocity profiler–pressure difference method

Boris Ouriev, Erich J. Windhab

Measurement Science and Technology · 2003 · 20 citations · 3 references

Concepts

Abstract

In the present work, the transient pressure driven shear flow of highly concentrated suspensions was investigated. The authors applied a novel Doppler-based ultrasound velocity profiler (Met-Flow SA)–pressure difference (UVP–PD) methodology (Ouriev B 2000 PhD Thesis Zurich ISBN: 3-905609-11-8, Ouriev B and Windhab E 2002 J. Exp. Fluids 32 204–11), for the investigation of concentrated suspensions in steady and transient flows.

References

3