Infection Control and Hospital Epidemiology · 2007 · 24 citations · 5 references
Life SciencesHematologyMicrobiologyBacteriologyDiagnostic MicrobiologyMedical MicrobiologyBacterial InfectionsBloodstream InfectionsClinical BacteriologyDiagnostic BacteriologyHealthcare-associated InfectionsMedical BacteriologyBacteriological ContaminationPeripheral Intravenous CathetersRisk Factors For Bloodstream InfectionSurveillance Of Catheter-associated Infections
We investigated an outbreak of infection in 10 patients with blood cultures positive for B. cepacia. All patients had indwelling intravenous catheters. Though we did not identify the source of the organism, our findings support the hypothesis that cross-contamination of multidose medications through the use of the same needle and syringe was a contributing factor.
5
Rodrigo Martino, Lucía Gómez, R. Pericás et al. · European Journal of Clinical Microbiology & Infectious Diseases · 2000 · 41 citations