Journal of Asian Architecture and Building Engineering · 2011 · 30 citations · 1 references
EngineeringCivil EngineeringBuilding StructuresEarthquake EngineeringStructural EngineeringBrick UnitsEarthquake Response Of StructuresReinforced Concrete StructuresStructural MechanicsStructural Response AnalysisStructural SystemsBrick Structural PerformanceBuilding Seismic ResponseCyclic LoadingReinforced ConcreteReinforced Concrete Seismic ResponseSeismic PerformanceSeismic Performance Of Buildings
This paper describes the effects of nonstructural brick walls on the seismic performance of reinforced concrete (R/C) buildings. Experimental and analytical studies were conducted on two buildings: one of which collapsed and the other suffered moderate damage due to the 2007 Sumatra, Indonesia earthquakes. A brick wall was extracted from the moderately damaged building and transported to Japan from Indonesia to experimentally evaluate its seismic performance. Two R/C one-bay frame specimens were constructed, and the imported wall was installed in one of the specimens. Comparing the seismic performance of specimens with and without the brick wall through quasi-static cyclic loading tests, wall contributions were quantitatively evaluated. Moreover, the seismic performance of the earthquake-damaged Indonesian buildings was evaluated numerically considering the findings of the tests. The analyses revealed a possible reason for the collapse of one of the buildings due to the earthquakes.
1