Evaluation of diagnostic ultrasound as a mass screening technique for the detection of hydatid cysts in the liver and lung of sheep and goats

A. Sage, Timothy Wachira, E. Zeyhle, E. Weber, E.M. Njoroge, Gary Smith

International Journal for Parasitology · 1998 · 53 citations · 8 references

DOIFull text

Open access

Concepts

Abstract

Ultrasound examination of the liver and lung followed by post-mortem examination was performed in 16 sheep and 284 goats. Thirty-one (10.3%) were positive for hydatid cysts on ultrasound examination and 46 (15.3%) were positive on post-mortem examination. Twenty-one positive on post-mortem examination were falsely identified as negative on ultrasound examination. Of the 254 animals negative on post-mortem examination, six (2.4%) were falsely identified as positive on ultrasound examination. The sensitivity and specificity of ultrasound examination for detecting hydatid cysts in sheep and goats was 54.36% and 97.64%, respectively (positive predictive value: 80.64%; negative predictive value: 92.19%).

References

8