Circulation · 1973 · 32 citations · 6 references
MedicineCardiologySurgeryCardiothoracic RadiologyCardiothoracic SurgeryClinical CardiologyCardiac CatheterizationCardiac Valve SurgeryCardiovascular ImagingEchocardiographic Hemodynamic AssessmentMitral Valve DiseaseValvular Heart Disease ImagingClinical SymptomsMitral Valve EvaluationProsthetic Heart Valve ImagingProsthetic Valve AssessmentProsthetic Valve EvaluationProsthetic Valve ManagementProsthetic Valve ObstructionValve Replacement Imaging
Forty-nine patients whose clinical symptoms suggested a leaking cardiac prosthetic valve were studied by both cineradiography and angiocardiography. We found a wider range of tilting motion of the nonleaking mitral valve than has been previously shown. An angle of tilt greater than 6° for the prosthetic aortic valve strongly suggests separation of the prosthesis from its bed with a paravalvular leak, while the angle of tilt suggestive of a paravalvular leak for a prosthetic mitral valve is 12°. However, a tilt of less than these values does not entirely exclude the existence of a leak. We strongly suggest that routine cineradiography be done in each patient shortly after surgery, as a basis for comparison if the patient later develops a murmur or congestive heart failure.
6
Prosthetic Heart Valve Surgery: Evaluation of Early and Late Complications
Safuh Attar, Elijah Saunders, Joseph S. McLaughlin et al. · The Annals of Thoracic Surgery · 1966 · 24 citations · Full text
Medicine, Cardiology, Surgery +14