Corrosion behavior of Type 316L (UNS S31603) stainless steel piping used in integrated coal gasification combined cycle (IGCC) plant facilities processing coal (0.9 MPa to 1.1 MPa and 150°C to 300°C) and industrial waste (0.11 MPa and 40°C to 60°C) was explained using scanning electron microscopy-energy dispersive x-ray spectrometry (SEM/EDS), x-ray diffraction (XRD), and a thermodynamic Ellingham-Pourbaix stability diagram. Material wastage and pitting were observed on the inner wall of Type 316L stainless steel piping used in Institute for Advanced Engineering (IAE) coal and industrial waste syngas plant facilities after 720 h and 170 h (total hours) of operation, respectively. Relevant corrosion mechanism was suggested based on SEM/EDS examination and thermodynamic inferences: the observed material wastage and corrosion behavior of the Type 316L piping material cut off from the coal syngas IGCC plant were explained by combined effects of evaporation of iron chlorides and subsequent transformation into thin oxides. On the other hand, the pitting corrosion phenomenon observed on the inner wall of Type 316L piping cut off from industrial waste processing IGCC plant was attributed to modified pitting mechanism caused by the preferential growth of corrosion pits in horizontal direction under aqueous condensate environment containing hydrochloric acid (HCl).