Circulation · 2013 · 133 citations · 24 references
MedicineCardiologyNuclear MedicineCardiac Nuclear MedicineClinical CardiologyDiagnostic ImagingCardiac ImagingCardiac Risk AssessmentCardiovascular ImagingIschemic Heart DiseaseIschemic Heart Disease EvaluationMyocardial Perfusion ImagingCardiac Myocardial Perfusion ImagingImaging-based Risk AssessmentIschemic Heart Disease ImagingMyocardial Perfusion ScintigraphyPrognostic Cardiac ImagingProspective Cohort DataSingle-photon Emission Computed Tomography Perfusion ImagingSingle-photon Emission Computed Tomography Perfusion Quantification
BACKGROUND: Appropriate use criteria (AUC) have been developed to aid in the optimal use of single-photon emission computed tomography (SPECT)-myocardial perfusion imaging (MPI), a technique that is a mainstay of risk assessment for ischemic heart disease. The impact of appropriate use on the prognostic value of SPECT-MPI is unknown. METHODS AND RESULTS: A prospective cohort study of 1511 consecutive patients undergoing outpatient, community-based SPECT-MPI was conducted. Subjects were stratified on the basis of the 2009 AUC for SPECT-MPI into an appropriate or uncertain appropriateness group and an inappropriate group. Patients were prospectively followed up for 27±10 months for major adverse cardiac events of death, death or myocardial infarction, and cardiac death or myocardial infarction. In the entire cohort, the 167 subjects (11%) with an abnormal scan experienced significantly higher rates of major adverse cardiac events and coronary revascularization than those with normal MPI. Among the 823 subjects (54.5%) whose MPIs were classified as appropriate (779, 51.6%) or uncertain (44, 2.9%), an abnormal scan predicted a multifold increase in the rates of death (9.2% versus 2.6%; hazard ratio, 3.1; P=0.004), death or myocardial infarction (11.8% versus 3.3%; hazard ratio, 3.3; P=0.001), cardiac death or myocardial infarction (6.7% versus 1.7%; hazard ratio, 3.7; P=0.006), and revascularization (24.7% versus 2.7%; hazard ratio, 11.4; P<0.001). Among the 688 subjects (45.5%) with MPI classified as inappropriate, an abnormal MPI failed to predict major adverse cardiac events, although it was associated with a high revascularization rate. Furthermore, appropriate MPI use provided incremental prognostic value beyond myocardial perfusion and ejection fraction data. CONCLUSIONS: When performed for appropriate indications, SPECT-MPI continues to demonstrate high prognostic value. However, inappropriate use lacks effectiveness for risk stratification, further emphasizing the need for optimal patient selection for cardiac testing.
24
Prediction of Coronary Heart Disease Using Risk Factor Categories
Peter W.F. Wilson, Ralph B. D’Agostino, Daniel Levy et al. · Circulation · 1998 · 9.6K citations
Optimal Medical Therapy with or without PCI for Stable Coronary Disease
William E. Boden, Robert A. O’Rourke, Koon Teo et al. · New England Journal of Medicine · 2007 · 4.7K citations · Full text
Exercise Myocardial Perfusion SPECT in Patients Without Known Coronary Artery Disease
Rory Hachamovitch, Daniel S. Berman, Hosen Kiat et al. · Circulation · 1996 · 839 citations