Radiology · 2004 · 393 citations · 24 references
MedicineOncologyRadiologyDiagnostic ImagingDiagnostic RadiologyHybrid ImagingComputed TomographyNeck Cancer ImagingNeck ImagingOncologic Hybrid ImagingPositron Emission TomographyTumor Detection18F-fluorodeoxyglucose ImagingAccuracyDiagnostic Accuracy StudiesLesion ClassificationMcnemar's TestPet Attenuation CorrectionPet-computed TomographyPositron Emission Tomography Attenuation Correction
PURPOSE: To compare diagnostic accuracy of attenuation-corrected positron emission tomography (PET) with fused PET and computed tomography (CT) in patients with head and neck cancer and to evaluate the effect of PET/CT findings on patient care. MATERIALS AND METHODS: Studies of 68 patients were reviewed by two physicians in consensus. Focal fluorodeoxyglucose (FDG) uptake in the head and neck on attenuation-corrected PET images was graded as benign, equivocal, or malignant. CT and PET/CT images were then reviewed, and initial findings were amended if necessary. Comparison was performed on a lesion-by-lesion basis. Accuracy was evaluated on the basis of follow-up and histopathologic findings. Potential effects on patient care were assessed by a head and neck surgeon. PET and PET/CT accuracy was compared with a McNemar test adjusted for clustering. RESULTS: A total of 157 foci with abnormal FDG uptake were noted, two of which were seen only on PET/CT images. PET/CT images were essential in determining the exact anatomic location for 100 lesions (74% better localization in regions previously treated surgically or with irradiation vs 58% in untreated areas; P =.06). On the basis of PET findings alone, 45 lesions were considered benign; 39, equivocal; and 71, malignant. With PET/CT, the fraction of equivocal lesions decreased by 53%, from 39 of 155 to 18 of 157 (P <.01). PET/CT had a higher accuracy of depicting cancer than did PET (96% vs 90%, P =.03). Six proved malignancies were missed with PET, but only one was missed with PET/CT. PET/CT findings altered the care for 12 (18%) of 68 patients. CONCLUSION: PET/CT is more accurate than PET alone in the detection and anatomic localization of head and neck cancer and has the clear potential to affect patient care.
24
A combined PET/CT scanner for clinical oncology.
Thomas Beyer, D.W. Townsend, T. Brun et al. · PubMed · 2000 · 1.6K citations
Stefan Adams, Richard P. Baum, Tankred Stuckensen et al. · European Journal of Nuclear Medicine and Molecular Imaging · 1998 · 488 citations
Medicine, Nuclear Medicine, Oncology +17
Uptake in supraclavicular area fat ("USA-Fat"): description on 18F-FDG PET/CT.
Christian Cohade, Medhat Osman, Harpreet K. Pannu et al. · PubMed · 2003 · 444 citations
Comparison of CT and MR imaging in staging of neck metastases.
Hugh D. Curtin, Hemant Ishwaran, A A Mancuso et al. · Radiology · 1998 · 392 citations