Ultrasound in Obstetrics and Gynecology · 2011 · 180 citations · 27 references
MedicineObstetricsObstetric UltrasoundUltrasonographyUltrasoundFetal AssessmentFetal BiometryFetal Growth AssessmentFetal ImagingGestational Age AssessmentGestational Age EstimationAbdominal Circumference AssessmentAbdominal Circumference MeasurementFemur Length AssessmentFemur Length MeasurementGestational Age MeasurementInterobserver ReproducibilityInterobserver Variability In BiometryMeasurement Variability
OBJECTIVE: To assess intra- and interobserver variability of fetal biometry measurements throughout pregnancy. METHODS: A total of 175 scans (of 140 fetuses) were prospectively performed at 14-41 weeks of gestation ensuring an even distribution throughout gestation. From among three experienced sonographers, a pair of observers independently acquired a duplicate set of seven standard measurements for each fetus. Differences between and within observers were expressed in measurement units (mm), as a percentage of fetal dimensions and as gestational age-specific Z-scores. For all comparisons, Bland-Altman plots were used to quantify limits of agreement. RESULTS: When using measurement units (mm) to express differences, both intra- and interobserver variability increased with gestational age. However, when measurement of variability took into account the increasing fetal size and was expressed as a percentage or Z-score, it remained constant throughout gestation. When expressed as a percentage or Z-score, the 95% limits of agreement for intraobserver difference for head circumference (HC) were ± 3.0% or 0.67; they were ± 5.3% or 0.90 and ± 6.6% or 0.94 for abdominal circumference (AC) and femur length (FL), respectively. The corresponding values for interobserver differences were ± 4.9% or 0.99 for HC, ± 8.8% or 1.35 for AC and ± 11.1% or 1.43 for FL. CONCLUSIONS: Although intra- and interobserver variability increases with advancing gestation when expressed in millimeters, both are constant as a percentage of the fetal dimensions or when reported as a Z-score. Thus, measurement variability should be considered when interpreting fetal growth rates.
27
A H BECKETT, M ROWLAND, P TURNER · The Lancet · 1965 · 16.9K citations
4 million neonatal deaths: When? Where? Why?
Joy E Lawn, Simon Cousens, Jelka Zupan · The Lancet · 2005 · 3.7K citations
Statistical methods for assessing observer variability in clinical measures.
Paul Brennan, Alan J. Silman · BMJ · 1992 · 990 citations · Full text