Anaesthesia · 1995 · 10 citations · 21 references
MedicinePediatricsCritical Care MedicineHemodynamic ManagementPulmonary Function TestingCardiovascular MonitoringMechanical VentilationCorrelationCritical Care HemodynamicsHemodynamic Monitoring ModalitiesWater Column Analysis
A prospective study was conducted to compare simultaneous intrathoracic and intra-abdominal central venous pressures in 10 critically ill, ventilated paediatric intensive care patients. Central venous pressures were measured using the water column technique over a 6 h study period. There was excellent correlation between intrathoracic and intra-abdominal vena caval pressure measurements (r = 0.974, p < 0.001). The difference between paired measurements did not exceed the limits of agreement (+/- 2SD, -2.36 to 4.42 cm H2O). The mean (SD) difference between readings was small (1.03 +/- 1.69 cmH2O) and was within clinically tolerable limits. These data suggest a clinically useful, close relationship between intra-abdominal and conventional intrathoracic central venous pressure measurement in this group of patients.
21
A H BECKETT, M ROWLAND, P TURNER · The Lancet · 1965 · 16.9K citations
J. I. Sznajder · Archives of Internal Medicine · 1986 · 494 citations
Medicine, Internal Medicine, Surgery +11
Accurate placement of central venous catheters
William T. McGee, Barbara L. Ackerman, LAWRENCE R. ROUBEN et al. · Critical Care Medicine · 1993 · 223 citations