Journal of Cardiovascular Electrophysiology · 2012 · 20 citations · 19 references
MedicineCardiologyRadiologyCardiothoracic SurgeryInterventional CardiologyPulmonologyAugmented Reality In MedicineDiagnostic Imaging SystemsFluoroscopy-guided ProceduresMedical Imaging InstrumentationAnatomical Overlay RegistrationOverlay AccuracyProjection In Three-dimensional GeometryPulmonary Vein IsolationRegistration AccuracyThree-dimensional Coordinate GeometryThree-dimensional Electroanatomic MappingThree-dimensional Fluoroscopy
BACKGROUND: Despite the advancement of technology in electroanatomic mapping systems (EAMS), fluoroscopy remains a necessary, basic imaging modality for electrophysiology procedures. We present a feasibility study of new software that enables 3D-augmented fluoroscopy in biplane catheterization laboratories for planning and guidance of pulmonary vein isolation (PVI). The computer-assisted overlay registration accuracy was assessed in a clinical setting using an automatic calculation of overlay projection geometry that was derived from hardware sensors in C-arms, detectors, and patient table. METHODS: Consecutive patients (n = 89) underwent left atrium (LA) magnetic resonance imaging MRI scan prior to PVI. Ideal ablation lines encircling the ipsilateral pulmonary veins (PVs) at antral level were drawn onto the segmented LA surface. The 3D-model was superimposed onto biplane fluoroscopy and matched with angiographies of LA and PVs. Three-dimensional-overlay projection geometry was automatically calculated from C-arm, detectors, and table sensors. Accuracy of technique was assessed as alignment of MRI-derived 3D overlay and angiographic LA/PV anatomy. Integrity of registered overlay was quantified using landmark measurements. RESULTS: Alignment offsets were 1.3 ± 1.5 mm in left PV, 1.2 ± 1.5 mm in right PV, and 1.1 ± 1.4 mm in LA roof region. Bravais-Pearson correlation of the landmark measurements was r = 0.978 (s < 0.01), mean offset between landmark distance measurements was 1.4 ± 0.78 mm. Average time needed for overlay registration was 9.5 ± 3.5 seconds. CONCLUSIONS: MRI-derived 3D-augmented fluoroscopy demonstrated a high level of accuracy when compared with LA/PV angiography. The new system could be especially useful to guide procedures not supported by EAMS, such as cryotechnique PVI.
19
Initiation of Atrial Fibrillation by Ectopic Beats Originating From the Pulmonary Veins
Shih‐Ann Chen, Ming-Hsiung Hsieh, CHING‐TAI TAI et al. · Circulation · 1999 · 1.5K citations
Medicine, Cardiology, Pharmacology +16
Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Hakan Oral, Bradley P. Knight, Hiroshi Tada et al. · Circulation · 2002 · 1.1K citations
Pulmonary Vein Anatomy in Patients Undergoing Catheter Ablation of Atrial Fibrillation
Ritsushi Kato, Lars Lickfett, Glenn R. Meininger et al. · Circulation · 2003 · 492 citations
Medicine, Cardiology, Radiology +13
Small or Large Isolation Areas Around the Pulmonary Veins for the Treatment of Atrial Fibrillation?
Thomas Arentz, Reinhold Weber, Gerd Bürkle et al. · Circulation · 2007 · 353 citations
Medicine, Cardiology, Surgery +17