A New Method for Detecting Leaks in Underground Water Pipelines

Andrea Cataldo, Giuseppe Cannazza, Egidio De Benedetto, Nicola Giaquinto

IEEE Sensors Journal · 2011 · 104 citations · 13 references

Concepts

TL;DR

Water distribution systems lose significant volumes to leaks, yet existing detection methods are time‑consuming, require expert operators, and fail under high‑pressure conditions. The study aims to develop a non‑invasive, time‑efficient leak detection system for underground metal pipes. The authors present a time‑domain reflectometry system that measures reflected signals to locate leaks, incorporates an accuracy‑enhancement strategy, and is validated through experiments comparing it with conventional surveys. The system accurately pinpoints leaks and reduces inspection time dramatically.

Abstract

In most water distribution systems, a fairly sizable amount of water is lost because of leaks and faults in pipes. For this reason, the individuation of leaks is extremely important for the optimization and rationalization of water resources. However, the techniques and methodologies that are currently used for the individuation of leaks, despite being universally accepted, are extremely time-consuming and require highly-experienced personnel. Additionally, such techniques become unreliable and ineffective when the measurements are not performed in specific operating conditions of the pipe (e.g., high water pressure). On this basis, in this paper, a time domain reflectometry (TDR)-based system for the non-invasive detection of leaks in underground metal pipes is presented. Not only does the adoption of the developed system leads to accurately pinpoint the leak, but it also allows to dramatically reduce the required inspection times. The TDR-based system for leak detection is described in detail (with particular attention to the measurement principle behind the method and to the methodology). Furthermore, a strategy for enhancing the accuracy in pinpointing the leak is addressed. The proposed system is validated through experimental campaign that consisted in carrying out a leak-detection survey through the traditional methods and through the proposed method.

References

13