American Journal of Veterinary Research · 2009 · 10 citations · 20 references
MedicineNephrologyVeterinary PhysiologyFeline Internal MedicineKidney TransplantationRenal PathophysiologyRenal IschemiaRenal Ischemic InjuryRenal PhysiologyAssayFluorescence Resonance Energy TransferIncubation Period OptimizationOrgan Ischemia-reperfusion InjuryPlasma Renin ActivityResonance FluorescenceStandard Curve ConstructionSubstrate Concentration Control
OBJECTIVE: To evaluate the use of a commercially available 5-carboxyfluorescein-based, intramolecularly quenched, fluorescence resonance energy transfer (FRET) peptide substrate of renin for measurement of plasma renin concentration in cats. SAMPLE POPULATION: Plasma samples obtained during a previous study of renal autograft ischemia-reperfusion injury in 10 cats and samples of fetal bovine serum containing recombinant human renin (rh-renin). PROCEDURES: Experiments involving samples of fetal bovine serum containing rh-renin were conducted to identify a suitable control vehicle, optimal substrate concentration, and appropriate duration of incubation. With the use of the identified assay conditions, a standard curve was constructed to allow conversion of relative fluorescent units into values of renin concentration (ng/mL). Subsequently, plasma samples obtained from cats before and after renal autograft ischemia-reperfusion injury were assayed to determine endogenous renin concentration. RESULTS: Under conditions of a 1:50 substrate dilution and 4-hour incubation period, the assay detected small amounts of rh-renin in fetal bovine serum. A linear relationship (R(2) = 0.996) between the relative fluorescent units generated and exogenous rh-renin concentration was evident. The assay detected renin in plasma samples obtained from cats after renal autograft ischemia-reperfusion, and renin concentrations on days 1 and 2 after transplant differed significantly. CONCLUSIONS AND CLINICAL RELEVANCE: The study data indicated that the assay involving the FRET peptide substrate of renin is potentially a rapid and specific method for measurement of plasma renin concentration in cats.
20
Textbook of Medical Physiology
Roxie Morris · Physical Therapy · 1962 · 324 citations
Life Sciences, Anatomy, Physiology +12
Chollada Buranakarl, Sheerin Mathur, Scott A. Brown · American Journal of Veterinary Research · 2004 · 87 citations · Full text
A Continuous Fluorescence Assay of Renin Activity
G.T. Wang, Caroline Chung, Thomas F. Holzman et al. · Analytical Biochemistry · 1993 · 85 citations