Journal of Speech and Hearing Research · 1977 · 42 citations · 0 references
Health ProfessionsAudiologyOtolaryngologyClinical AudiologyHearing SciencePsychoacousticsAuditory Evoked PotentialsAuditory NeurophysiologyCochlear FunctionHearing ImpairmentHearing LossMiddle Latency ResponsesAmplitudes AnalysisAuditory Evoked Potential Latency AnalysisAuditory Middle Latency ResponsesCochlear ElectrophysiologyConductive Hearing Loss EffectsMiddle Latency Auditory Evoked PotentialsMiddle Latency Response AmplitudeMixed Hearing Loss Patterns
Tone-pips of 500, 1000, and 3000 Hz were presented at 0-, 10-, 20-, 35-, and 50-dB HL to 10 normal-hearing subjects and at 0-, 10-, 20-, 35-, and 50-dB SL to 10 subjects with conductive, sensorineural, or mixed hearing losses. Middle component (latencies 8-90 msec) averaged electroencephalic responses to the tone-pips were analyzed in terms of peak latencies and peak-to-peak amplitudes. Properties of the responses were generally the same for both normal-hearing and hearing-impaired subjects except that the hearing-impaired subjects showed slightly greater amplitudes overall. The small reduction in latencies with increasing stimulus frequency seen in the normal-hearing subjects was not observed in the hearing-impaired subjects.