Manufacturing of 50 kA superconducting transformer for ITER correction coil conductor test

H. J. Liu, Yu Wu, Zh. B. Ren, Songtao Wu, Yuejiang Shi, Jinqing Peng, J. L. Chen, Fu Long, Ming Yu, Li Qian

Review of Scientific Instruments · 2010 · 11 citations · 1 references

Concepts

Abstract

To meet the specifications of International Thermonuclear Experimental Reactor correction coil (CC) conductor, a 50 kA superconducting transformer has been designed and manufactured to provide the short sample of the CC conductor the current. The transformer consists of two concentric layer-wound superconducting solenoids with the primary inside the secondary coil. In order to test the transformer, the two legs of the secondary coil were directly connected by superconducting cables. A 500 W/4.5 K refrigerator was used to provide the supercritical helium. The maximum current of 56.3 kA in the secondary coil loop was obtained.

References

1