Duration of pulmonary function adaptation to ozone in humans

Thomas J. Kulle, Larry R. Sauder, H. David Kerr, Bernard P. Farrell, M. S. Bermel, Dennis M. Smith

American Industrial Hygiene Association Journal · 1982 · 60 citations · 0 references

Concepts

Abstract

The duration of pulmonary function adaptation subsequent to cessation of a 5-day repeated ozone (O3) exposure was studied in 24 nonsmoking human subjects. A three-week, 3 hr/day study was conducted. The subjects received filtered air on Week 1 and 0.4 ppm O3 on Week 2. During Week 3, 13 subjects were re-exposed to O3 on Friday and 11 were re-exposed to O3 on Tuesday. Spirometric measurements (FVC and FEV1) and bronchial reactivity to methacholine showed adaptation within 2-3 days of the repeated daily exposures (Week 2). Although the duration of adaptation seen with bronchial reactivity appears longer than 7-days, the FVC and FEV1 clearly demonstrated complete loss of adaptation by 7 days, with a trend toward significance by 4 days. We conclude, therefore, the loss of ozone adaptation in pulmonary function is a gradual phenomenon lasting less than 7 days following cessation of repeated daily exposures.