The Journal of Physical Chemistry C · 2009 · 202 citations · 26 references
EngineeringBiotechnologyChemistryAnalytical ChemistryBiosensorsElectrochemistryElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsEnzymatic BiosensorsEnzyme-based BiosensorsNanotubesBioactivityGlucose BiosensingGlucose BiosensorsGlucose OxidaseGlucose SensingGlucose SensorsTin-doped Indium OxideZinc Oxide Nanostructures
Highly oriented single-crystal ZnO nanotube (ZNT) arrays were prepared by a two-step electrochemical/chemical process on indium-doped tin oxide (ITO) coated glass in an aqueous solution. The prepared ZNT arrays were further used as a working electrode to fabricate an enzyme-based glucose biosensor through immobilizing glucose oxidase in conjunction with a Nafion coating. The present ZNT arrays-based biosensor exhibits high sensitivity of 30.85 μA cm −2 mM −1 at an applied potential of +0.8 V vs. SCE, wide linear calibration ranges from 10 μM to 4.2 mM, and a low limit of detection (LOD) at 10 μM (measured) for sensing of glucose. The apparent Michaelis−Menten constant K M app was calculated to be 2.59 mM, indicating a higher bioactivity for the biosensor.
26
Broadband ZnO Single-Nanowire Light-Emitting Diode
Jiming Bao, Mariano A. Zimmler, Federico Capasso et al. · Nano Letters · 2006 · 539 citations