Journal of Cataract & Refractive Surgery · 1990 · 47 citations · 10 references
MedicineOphthalmologySurgeryAnterior SegmentOphthalmic SurgeryRefractive SurgeryCataract AssessmentCataract EvaluationOcular BiometryPreoperative Refractive EvaluationAxial Length CorrelationAxial Length Prediction ModelsLinear RegressionMultiple RegressionPostoperative Refractive PredictabilityPreoperative Biometry
The postoperative intraocular lens (IOL) chamber depth was predicted using a multiple linear regression analysis of the postoperative chamber depth as a function of the corneal height, the preoperative chamber depth, and the axial length in 279 patients with a posterior chamber lens implant. Based on a linear regression formula incorporating these preoperatively defined parameters, the postoperative IOL chamber depth could be predicted with a correlation coefficient of 0.71 and an error of +/- 0.30 mm (SD). It is concluded that an individual prediction of the IOL chamber depth will improve the accuracy in IOL calculation.
10
Statistical Methods in Medical Research.
P. Armitage, George Berry · Biometrics · 1997 · 260 citations
Calculation of the optical power of intraocular lenses.
S N Fyodorov, M. A. Galin, Arthur Linksz · PubMed · 1975 · 129 citations
Medicine, Ophthalmology, Surgery +15
Intraocular lens calculation: the problem of the short eye.
Kenneth J. Hoffer · PubMed · 1981 · 65 citations